| Traps and notifications can be sent using the command <CODE>'snmptrap'</CODE>. | | Traps and notifications can be sent using the command <CODE>'snmptrap'</CODE>. |
− | The following examples generate the generic trap <CODE>'coldStart'</CODE> and a | + | The following examples generate the generic trap <CODE>'warmStart(1)'</CODE> and a |
| (dummy) enterprise specific trap '99' respectively: | | (dummy) enterprise specific trap '99' respectively: |
| | | |
− | snmptrap -v 1 -c public localhost "" "" 0 0 "" | + | snmptrap -v 1 -c public localhost "" "" 1 0 "" |
| snmptrap -v 1 -c public localhost "" "" 6 99 "" | | snmptrap -v 1 -c public localhost "" "" 6 99 "" |
| | | |
|
|
| snmptrap -v 2c -c public localhost "" .1.3.6.1.4.1.2021.251.1 | | snmptrap -v 2c -c public localhost "" .1.3.6.1.4.1.2021.251.1 |
| | | |
− | (These two are equivalent ways of specifying the same trap). | + | (These two are equivalent ways of specifying the same trap). Again, |
| + | the empty parameter "" will use a suitable default for the relevant |
| + | value (<CODE>sysUptime</CODE>). |
| + | |
| | | |
| Any of these commands can be followed by one or more varbinds, | | Any of these commands can be followed by one or more varbinds, |
|
|
| snmptrap -v 2c -c public localhost "" ucdStart sysContact.0 s "Dave" | | snmptrap -v 2c -c public localhost "" ucdStart sysContact.0 s "Dave" |
| | | |
Exception encountered, of type "Error"